maxi m u m ratings t ypical ope r ati o n c lass of t ype of s ervice p late p late p late s creen p late drive output operation voltage c urrent voltage voltage c urrent p ower p ower (volts) ( a mps) (volts) (volts) ( a mps) (watts) (kilowatts) a b1 rf linear amplifer 3,000 0.60 2,000 350 0.50 --- 0.550 a b1 rf linear amplifer 3,000 0.60 2,800 350 0.57 --- 0.975 the 4CX600JB is the lower priced version of the highly linear 4cx600j. this type is recommended when operation is to be class ab1 or when extra drive power is available for ab2 operation. 4 cx 600jb cpi | 4 c w50,000j for information on this and other cpi products, visit our website at: www.cpii.com , or contact: cpi mpp division, eimac operation, 607 hansen way, palo alto, ca 94303 telephone : 1(800) 414-8823. fax : (650) 592-9988 | email : powergrid@cpii.com the values listed above represent specifed limits for the product and are subject to change. the data should be used for basic information only. formal, controlled specifcations may be obtained from cpi for use in equipment design. c ha r acte r istics plate dissipation (max.) 600 watts screen dissipation (max.) 15 watts grid dissipation (max.) 1 watt frequency for max. rating (cw) --- mhz amplifcation factor --- filament/cathode oxide coated voltage 6.0 volts current 5.4 amps capacitance grounded cathode input 50 pf output 6.3 pf feedthrough .13 pf capacitance --- input --- pf output --- pf feedthrough --- pf cooling forced air base 9 pin special air socket sk-607 air chimney sk-646 boiler --- length 2.71 in; 68.80 mm diameter 2.08 in; 52.8 mm weight 7.7 oz; 218 gm cpi | 4 cx 600jb
|